Removing
Disconnect the battery ground wire.
Remove the suction pipe.
In the installed state, check the ease of movement of the fan wheel.
Remove the lower cover in the upper part of the footwell in front of the storage box.
Press down with a screwdriver holding the tongue (arrow). Pull out the fan by turning it clockwise.
Attention: If the heater fan does not work at all stages, then, as a rule, there is a defect in the additional resistance. In this case, replace the connecting plug in the kit.
To do this, press the retaining clip down and pull the connector down.
Installation
Attach and fix the connecting plug.
Attention: Lubricate the groove and the spring of the contact surfaces to make it easier. The connection socket must be firmly seated on the housing, otherwise screw the connection from above.
Turning to the left, insert and fix the fan.
Install cover.
Install the suction pipe.
Connect the battery ground wire.