Examination
Switch off the ignition. Disconnect the switch connector. Having connected an ohmmeter to the terminals of the switch block, measure its resistance, which should be zero with the throttle closed and equal to «infinity» with open throttle.
Adjustment
Loosen the screws securing the switch (pic. 2-203). Insert a feeler gauge 1 0.15 mm thick between the actuator lever and throttle stop. Move the throttle valve to the switching position of the switch contacts. At the same time, a click should be heard.
Tighten the switch mounting screws and check the adjustment again. Connect the switch connector.