Dismantling
Pic. 2.134. valve connector
Disconnect connector 1 (pic. 2.134).
Unscrew the screws and remove the valve 1 of the variable valve timing system from the housing.
Note: Seals and O-rings must always be replaced.
Installation
Moisten the O-ring with engine oil.
Note: The variable valve timing system valve 1 and the housing must be free of dirt.
Note: A new valve 1 for variable valve timing must be taken out of the packaging immediately before installation.
Carefully insert the valve 1 of the phase shifter into the housing and press it by hand until it stops, vertically relative to the axis of the valve.
Tighten the screws with 4 Nm.
Further assembly is carried out, respectively, in the reverse order of dismantling.