Removing
Disconnect the connector from the coolant temperature sensor at the outlet of the radiator.
Note: Gaskets and O-rings must be replaced.
Note: Drain the coolant.
Note: Remove the three-phase generator
Remove the coolant hose from the fitting.
Loosen the fixing bolts 4 of the fitting 3 using the articulated wrench 10, unscrew using the nozzle 5 and remove the fitting 3 with the thermostat 1.
Thermostat 1 1/4 rev. (90°) turn to the left and remove from the connecting fitting 3.
Installation
Installation is carried out in the reverse order, taking into account the following.
Moisten the new O-ring 2 with coolant.
Pic. 2.335. Thermostat components
Install thermostat 1 in connection 3 and make 1/4 rev. (90°) rotate right (pic. 2.335).
Note: The thermostat brackets must be nearly vertical.
Note: Install the connecting fitting 3 with thermostat 1 in the cylinder block.
Tighten the fixing bolts 4 using the articulated wrench 10. Tightening torque 15 Nm.
Fill with coolant.