Check condition
Work is carried out on a cold engine.
Work order
Unscrew the clamp connection between the exhaust pipe and the intermediate muffler.
Pic. 2.372. Installation scheme for clamping clamps
Install a clamping collar with a distance of A = 5 mm in front of the marking on the exhaust pipe and slightly tighten the front connection (pic. 2.372).
Pic. 2.373. Installation of intermediate and main mufflers
Install the intermediate and main muffler forward in the clamping collar until the dimension A is reached between the mount/body and the mount/main muffler of 4 mm. indicates the direction of movement (pic. 2.373).
Align the main muffler horizontally.
Tighten the clamping collar connections in this position.
Tightening torque: M8 - 25 Nm.
Tightening torque: M10 - 40 Nm.
After tightening the clamping collar, check dimension A and correct if necessary.