Attention! The contact of the interrupter with the cam withstands approximately 30,000 km of run.
Removing
Remove the distributor cap and slider.
Disconnect connector "With", unscrew the screw "A" and remove the breaker contact.
Installation
Lubricate the contact bearing with a drop of oil.
Install a breaker contact. Lubricate the sliding surface of the cam and the plastic cam on the contact with a small amount of universal grease.
Carefully remove any oil or grease from the contact surfaces. The contact surfaces must be parallel to each other.
Connect the wire to the breaker contact.
Adjust the angle of the closed state of the breaker contacts.
Install slider.
Inspect the ignition distributor cap for cracks and traces of surface leakage currents.
Clean the cover inside and out. Replace defective cover.
Check the position and condition of the carbon contact, install the distributor cap.
Adjust ignition timing.